Resumo
Background: The efficacy of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy-defibrillator (CRT-D) therapy has already been established in clinical trials but their effectiveness in several clinical settings remains undetermined. This study aimed to assess the effectiveness of ICD and CRT-D therapies within the Brazilian National Health System (SUS). Methods: All patients who underwent ICD or CRT-D implantation within the SUS from 2001 to 2007 were included in the study. We compared estimated Kaplan-Meier survival curves using the Peto’s test. Prognostic factors were selected using Cox’s models. Results: There were included 3,295 patients in the ICD group and 681 patients in the CRT-D group. Cardiac causes accounted for 79% of all deaths in both groups and Chagas’ heart disease accounted for 31% of these deaths. In the CRT-D group, survival significantly decreased around the fourth year of follow-up, with a decrease from 59.5% to 38.3% in 5.5 months. Transvenous implantation technique was used in 62% of CRT-D patients. In-hospital case-fatality rates were higher in those undergoing surgical implantation (5.3%) than those undergoing transvenous implantation (1.6%) (p = 0.02). Conclusions: The results show that short-term, medium-term and long-term effectiveness of ICD therapy appears to be similar to that evidenced in clinical trials. In the CRT-D group, in-hospital case-fatality and 30-day case-fatality were higher than those reported in other studies. Surgical epicardial implantation technique was performed in this group at a higher frequency than that reported in the literature and was associated with poorer short-term prognosis.
Description
Palavras-chave
Implantable defibrillators, Cardiac resynchronization therapy devices, Chagas cardiomyopathy, Survival analysis, Medical record linkage, Technology assessment, Hospital mortality, High-cost technology
Citação
Migowski A, Ribeiro AL, Carvalho MS, Azevedo VMP, Chaves RBM, Hashimoto LA et al. Seven years of use of implantable cardioverter-defibrillator therapies: a nationwide population-based assessment of their effectiveness in real clinical settings. BMC Cardiovasc Disorder 2015 Mar;13;15(22). doi: 10.1186/s12872-015-0016-2. PMID: 25888219; PMCID: PMC4364497.